Type
Digital Multimeter
Maximum Capacitance
9999 microfarads
Maximum Frequency
99.99kHz
Insulation measurement range
0.01 megaohms to 2 gigohms
Insulation test voltages
50V, 100V, 250V, 500V, 1000V
Resistance
0.1 ohms to 50 megaohms
Temperature probe and range
K-type thermocouple -40 to +537 degrees C/-40 to +998 degrees F
Weight
550g
Power Supply
4 AA batteries (NEDA 15A or IEC LR6)
Dimension
5.0 x 10.0 x 20.3cm (H x W x D)
Key Features
Manual- and auto-ranging digital insulation multimeter measures insulation resistance, current, voltage, capacitance, frequency, resistance, and temperature, and performs diode tests for testing line insulation on motors, generators, cables, and switch gear
True RMS meter provides accurate readings when measuring linear or nonlinear loads where the current or voltage has an undistorted or distorted waveform
Insulation test voltages of 50, 100, 250, 500, and 1000V and insulation measurement range of 0.01 megohms to 2 gigohms
Low-pass filter blocks unwanted voltages when measuring AC voltage and AC frequency to provide accurate measurements on inverters and variable-frequency motor drives
Ingress Protection certified IP40; European Conformity (CE) marking; UL 61010-1; ANSI/ISA S82.01-2004; CAN/CSA C22.2 No. 1010.1:2004; IEC safety standards 61010-1:1002 and 61010.1-04, IEC61557-1; IEC61557-2; and IEC/EN 61010-1, 2nd edition for Category III installations up to 1000V and Category IV installations up to 600V, and Pollution Degree 2
Insulation test voltages 50 volts; 100 volts; 250 volts; 500 volts; 1,000 volts
Live circuit detection prevents insulation test if voltage of more than 30 volts is detected
Auto-discharge of capacitive voltage for added user protection
AC/DC voltage, DC milliVolts, AC/DC milliamps, resistance, continuity
Testing for capacitance, diode, temperature, min/max, and frequency